The reasons for weak light output, no light output, and fracture of the laser tube are as follows:
① Whether the water pressure and flow are normal; Is the water flow direction low in and high out.
② Will there be bubbles inside the laser tube.
③ Are there any discounts on the water pipes of the waterway.
④ Is the luminescence working under the control of someone's protection.
⑤ The water temperature should be controlled around 30 degrees Celsius, and the cooling water in cold areas should not freeze, especially after the laser is shut down, and the cooling water should not be stored in the laser tube.
⑥ If all of the above are normal situations, it indicates that there is a problem with the quality of the laser tube itself.
The following image shows that the light inside the tube is normal, but there are many bubbles circulating in the water, which does not have a cooling effect and may result in weak light output or even a burst of the laser tube. Therefore, please check whether these conditions are normal before starting and using the tube. It's getting cold, you need to add antifreeze, antifreeze, antifreeze! Say important things three times